Airway Equipment

Endotracheal Tube and Laryngoscopes
 
 

Age

Weight

ET tube

Blade

< 28 weeks

<1000 g

2.5

0 Miller

28-34 weeks

1000-2000 g

2.5 - 3

0 Miller

34-38 weeks

2000 - 3000 g

3 - 3.5

0 Miller

term

> 3000 g 

3.5 - 4

1 Miller

3 mo

5.5 kg

4

1 Miller

6 mo

7

4

1 Miller

1 yr

10

4.5

1 Miller

2 yr

12

4.5

1.5 Miller

3

14

5

2 Miller/Mac

4

16

5.5

2 Miller/Mac

5

18

5.5

2 Miller/Mac

6-7

20-22

6

2 Miller/Mac

8-10

25-30

6.5

2 Miller/Mac

Adult Female

60

7

3 Miller/Mac

Adult Male

70

8

3,4 Miller/Mac

Estimation of Cuffed ET size (millimeters)  = 4 + age/4
Estimation of Cuffed ET size (millimeters)  = 4 + age/3

PEDS/ADULT:   ET tube depth of insertion (gum line) = 3 x (internal diameter)

setstats1